Desktop Breath Analyzer

Explore next level of durability and accuracy

Take the guesswork out of breath alcohol testing with Intoximeters – the trusted choice worldwide.

The benefits of electrochemical sensor (EC) fuel cell analysis and real-time analytical advantages of infrared sensor (IR) technology, in one dependable instrument.

Intoximeters offers a comprehensive selection of top-of-the-line breath alcohol testing devices, which are relied upon by many of the world’s most advanced alcohol testing initiatives. Our desktop units are unmatched in terms of quality and serve as evidential breath testing instruments.

Intox EC/IR® II

Bench-top instrument featuring fuel cell integration analysis combined with real-time analytical advantages of infrared technology.

Features

The sampling system in the Intox EC/IR II utilizes advantages of both electrochemical sensor (EC) and infrared sensor (IR) technology. The Infrared system is capable of monitoring in real time, both alcohol and carbon dioxide concentrations in the breath. The electrochemical sensor system is utilized to quantify the alcohol concentration in a breath sample.

Software settings and test database are monitored to insure their integrity. The instrument also contains advanced radio frequency interference immunity and detection, automatic accuracy checks and calibrations using internal gas tank or external simulator, self-diagnostic capabilities, an easy to read 256 x 32 pixel graphic vacuum fluorescent display and is capable of remote diagnostics along with centralized data collection using optional IntoxNet software.

Specificaitions
Analytical System Utilizes an Intoximeters electrochemical fuel cell sensor which generates an electrical response that is proportional to the alcohol concentration in the provided, fixed volume sample. The fuel sensor is highly selective for alcohol. It does not respond to acetone or other substances found in the human breath after a fifteen minute deprivation period. The instrument also utilizes and infrared detection system to monitor the breath sample for alcohol and carbon dioxide during the provide sample flow. The infrared data can be used to determine when deep lung breath has been achieved and to identify mouth alcohol events.
Measurement Types Direct Test / Manual Sample Direct Test / Automatic Sample
Measurement Range .000 to .440 g/210L (custom ranges and units of measure are available)
Accuracy and Precision Meets the NHTSA and OIML model specifications for Evidential Breath Test Devices
Environmental Limitations Instrument is designed to be used and has a proven track record in almost any environment that an operator could expose breath alcohol testing instruments to. Instrument operates in a wide range of temperatures, ambient humidity, and atmospheric pressures.
Supported Calibration System Automatic delivery of Dry Gas or Wet Bath Standards
Mouthpiece Available with a check valve built into the one time use mouthpiece
Visual Output Easy to read 256 x32 pixel graphic vacuum florescent display
Supported COM I/O RS232 Serial, Parallel, USB, PS2, Ethernet, optional Modem (prior versions required add-ons to provide USB and Ethernet support. Instruments in that original configuration are still available for purchase)
Print Capable Yes
Power Options Wall Current – 100-240 VAC Power for Printer – Instrument provides power for internal printer
Physical Instrument Dimensions - 19” x 14.5” x 7” Instrument Weight (with batteries) - 18.75 lbs
Approvals NHTSA (US DOT) EBT, Inquire for list of approved US states or certifications in countries outside of the USA. CE Mark
Standard Package Includes Printed Manual 100 Mouthpieces
Instrument Options IntoxNet Data Management Software Heated Simulator Tube Magnetic Card Reader Barcode Reader Digital Simulator with Electronic Control Monitoring Integrated Dry Gas Compartment External Printer
Training Intoximeters offers in person training and has a variety of training tools available to help a user cascade training to their own operators. Contact our training department for more information (or see Training section of our website at www.intox.com/training).

Request a Demo From One of Our Global Distributors Today!

Intox EC/IR® II.t

The Intox EC/IR II.t serves as a portable and reliable evidential instrument that caters to the diverse needs of on-the-go testing environments.

Compact and lightweight design, user-friendly features, and clear display, along with its built-in printer, offer a powerful solution to cater to your mobile evidential breath testing requirements.

Features

This transportable instrument utilizes advantages of both electrochemical sensor (EC) and infrared sensor (IR) technology. The Infrared system is capable of monitoring in real time, both alcohol and carbon dioxide concentrations in the breath. The electrochemical sensor system is utilized to quantify the alcohol concentration in a breath sample.

Software settings and test database are monitored to insure their integrity. The instrument also contains advanced radio frequency interference immunity and detection, automatic accuracy checks and calibrations using internal gas tank or external simulator, self-diagnostic capabilities, an easy to read display and is capable of remote diagnostics along with centralized data collection using optional IntoxNet software.

Specificaitions
Analytical System Utilizes an Intoximeters electrochemical fuel cell sensor which generates an electrical response that is proportional to the alcohol concentration in the provided, fixed volume sample. The fuel sensor is highly selective for alcohol. It does not respond to acetone or other substances found in the human breath after a fifteen minute deprivation period. The instrument also utilizes and infrared detection system to monitor the breath sample for alcohol and carbon dioxide during the provide sample flow.
Measurement Types Direct Test / Manual Sample Direct Test / Automatic Sample
Measurement Range .000 to .440 g/210L (custom ranges and units of measure are available)
Accuracy and Precision Meets the NHTSA and OIML model specifications for Evidential Breath Test Devices
Supported Calibration System Automatic delivery of Dry Gas. Wet Bath Standards delivery is manual through breath tube.
Environmental Limitations Instrument is designed to be used and has a proven track record in almost any environment that an operator could expose breath alcohol testing instruments to. Instrument operates in a wide range of temperatures, ambient humidity, and atmospheric pressures.
Mouthpiece Available with a check valve built into the one time use mouthpiece
Visual Output Easy to read, multi-line, backlit LCD
Supported COM I/O Serial, Parallel, PS2, optional Modem
Print Capable Instrument is available with an optional thermal printer or is capable of working with an off the shelf external printer
Power Options Wall Current – 100-240 VAC Power for Printer – Instrument provides power for internal printer
Physical Instrument Dimensions - 18.5” x 15” x 6” Instrument Weight (with batteries) - 15.75 lbs
Approvals NHTSA (US DOT) EBT, OIML, Inquire for list of approved US states or certifications in countries outside of the USA. CE Mark
Standard Package Includes Printed Manual 100 Mouthpieces
Instrument Options IntoxNet Data Management Software Heated Simulator Tube Magnetic Card Reader Barcode Reader Digital Simulator with Electronic Control Monitoring Integrated Dry Gas Compartment External Printer
Training Intoximeters offers in person training and has a variety of training tools available to help a user cascade training to their own operators. Contact our training department for more information (see Training section of our website at www.intox.com/training).